Pump Accessories

Bianco - Float & Weight
Bianco - Float & Weight

Bianco BIA-SK12 Float with 10 meters of H05 Neoprene Cable and Bianco BIA-SK12CWB 200g gland mounted Counterweight.

BIA-SK12/CWB

  • 240V
  • 1 ph
  • 10A Max.
  • “3 wire’
  • IP68
  • Max. 500
More Information
Brass Floating (side outlet) Foot Valve Complete with Plastic Floats
Brass Floating (side outlet) Foot Valve Complete with Plastic Floats

Floating Foot Valve. Foot Valves are made of Gunmetal Bronze, it has a side outlet threaded B.S.P. to take a pipe fitting, eliminating the need for a bend when being floated in a dam or river. There is a hanger bar with a tee to enable the foot valve to float between two Valve floats with stems screwed into the tee.

More Information
Prescontrol - Automatic Electronic Pressure Control
Prescontrol - Automatic Electronic Pressure Control

'Prescontrol' Automatic Electronic Pressure Control unit is programmed to perform all of the pump control operations automatically.

When breakdowns occur, such as water failure, obstruction of the suction pipe, etc. the unit can prevent damages caused by its working in the absence of water.

When there is no water in the system , the water pump will stop automatically after 20s running and the red led will glint. The water pump runs automatically for 40s after stopping for 10s and checks the water supply; If there's no water supply, the water pump runs automatically for 40s after stopping for 10s again and checks the water supply; If there's still no water supply, the water pump will stop automatically amd turn to dry-running protection status. After 24hrs the pump will start automatically and repeat the above procedures. During stopping of the pump, the water pump will start automatically if the flow through the controller is more than the starting flow.

Rectification of the failures that have caused the blockage allows the system to be restarted ny pressing the 'Restart' button.

 PRESCONTROL

  • Up to 1.5kW
  • 1” BSPM
More Information
Pressure Gauge
Pressure Gauge

63mm Liquid Filled, Stainless Steel Case, Lower Mount

Available 800 kPa and 1600 kPa

 

800kPa

  • 0-800 kPa
  •  ¼” BSPM

1600kPa

  • 0-1600 kPa
  •  ¼” BSPM
More Information
Square D Loss of Prime Pressure Swicth
Square D Loss of Prime Pressure Swicth

Designed for direct control of electrically driven pumps. Can be used with motor starters to control higher horsepower motors.

SQD-LOP

  • Pressure Range 138-449 kPa / 20-65 psi
  • Mount ¼” BSPF
  • Low pressure cut off level
More Information
Telemecanique - Automatic Pump Controller
Telemecanique - Automatic Pump Controller

XMP-12

  • Pressure Range 124-1200kPa / 18-174 psi
  • Mount ¼” BSPF

 

 

More Information
Trevi Logicstop
Trevi Logicstop

The Trevi LOGICSTOP is an electronic plug in device designed to protect your pressure switch controlled water pumps, or water pumps without controls from dry running and ultimately being destroyed. The LOGICSTOP stops the motor from running and will protect the pump in the case of water shortage caused through loss of prime or blockages. As the device plugs directly into the power point it does not need to be installed by an electrican.

LOGICSTOP

  • 230 VAC Single Phase Mains Voltage
  • ± 10% Acceptable Voltage Fluctuations
  • 50Hz Frequency
  • Min. 3A – Max. 8A
  • Operating Temperature Min. 50 Max. 450
  • 550 Max. Ambient Temperature
More Information
Wat-Mascontrol - Automatic Electronic Pressure Control
Wat-Mascontrol - Automatic Electronic Pressure Control

The 'Wat-Mascontrol1-1/4' Automatic Electronic Pressure Control unit is programmed to perform all of the pump control operations automatically.

When breakdowns occur, such as water failure, obstruction of the suction pipe, etc. the unit can prevent damages caused by its working in the absence of water.

When there is no water in the system , the water pump will stop automatically after 20s running and the red led will glint. The water pump runs automatically for 40s after stopping for 10s and checks the water supply; If there's no water supply, the water pump runs automatically for 40s after stopping for 10s again and checks the water supply; If there's still no water supply, the water pump will stop automatically amd turn to dry-running protection status. After 24hrs the pump will start automatically and repeat the above procedures. During stopping of the pump, the water pump will start automatically if the flow through the controller is more than the starting flow.

Rectification of the failures that have caused the blockage allows the system to be restarted ny pressing the 'Restart' button.

WAT-MASCONTROL1-1/4

  • Up to 2.2kW
  • 1 ¼ ” BSPM
More Information